Manual
InfoStation 5-Bay RAID User's Guide - Rev. C00 StorCase Technology, Inc.
RAID Configuration 45
MONITORING
This section describes Status window code colors, LED indicator status, and event log mes-
sages used to troubleshoot the InfoStation.
Monitoring Drive Status
The color of the drives in the Status window indicates the status of the drives.
Color State Definition Resolution
Green Normal Drive is active. N/A
Red Needs rebuild Drive has failed. Replace the failed
drive.
Gray or Red Unplugged Drive is offline. Verify that the drive is
Background will turn inserted. Replace if
red after a write to necessary.
the volume.
Light Blue New drive New drive. N/A
Yellow Rebuilding Drive is being rebuilt. N/A
Purple Wrong slot There is a mismatch be- Install the correct drive
tween Serial # and ex- into the bay.
pected Serial #. Drive
is in the wrong bay.