Owner manual
84 Appendix A - Specifications/Dimensions
StorCase Technology, Inc. InfoStation 10-Bay RAID User's Guide - Rev. E00
The following InfoStation specifications and dimensions are provided for reference only.
Appendix A - Specifications/Dimensions
Physical
Specifications
Rack Mount
Height
1.70" (43.2mm)
Width
17.49" (442.2mm)
Depth 19.80" (502.9mm)
(1)
Environmental Specifications
Operating
Storage
Ambient Temperature 0° C to 35° C -40° C to 70° C
Relative Humidity
(1)
10% to 80% 10% to 90%
Altitude
-1000 to 10,000 ft -1000 to 40,000 ft
-305m to 3048m -305m to 12195m
Shock
(2)
10g 60g
(1)
Non-condensing with maximum gradient of 10% per hour
(2)
11 msec pulse width 1/2 sine wave
Weight
27.2 lbs (12.4kg)
Weight of empty chassis (no drives installed)
Electrical
Specifications
(per 300W Power Supply Module)
AC Input
DC Output
Chassis Reliability/Maintainability
MTBF 120,000 Hours
Preventive
Maintenance
Power Supply Module
100 to 240 VAC, 50/60Hz
5V at 26A, 12V at 28A
Blower Module
I/O Module
26.8 CFM
Cooling
(per Fan
Module)
(1)