Kingston Technology Data Express® DE300i-S Removable 3-Bay SCSI Enclosure with Single-Ended 8-Bit I/O User's Guide
ii Kingston Technology's Data Express® DE300i-S Removable 3-Bay SCSI Drive Enclosure with 8-Bit Single-Ended User's Guide Part No. D89-0000-0021 B00 May 1997 Kingston Technology Company 17600 Newhope Street Fountain Valley, CA 92708-9885 Phone (714) 438-1850 Fax (714) 438-1847 Kingston Technology Company DE300i-S User's Guide - Rev.
iii Limited Warranty KINGSTON TECHNOLOGY COMPANY (“Kingston”) warrants that this product is free from defects in material and workmanship. Subject to the conditions and limitations set forth below, Kingston will, at its option, either repair or replace any part of this product which proves defective by reason of improper workmanship or materials.
iv CE Declaration of Conformity Company’s Name: Kingston Technology Company Storage Products Division Company’s Address: 17600 Newhope Street Fountain Valley, CA 92708 Manufacturer’s Address: 11535 Martens River Circle Fountain Valley, CA 92708 Product Name: Data Express DE300i Model Number: DE300i-XSXX/XXX Conforms to the following specifications: Safety Agencies: CSA “Certified” UL TÜV “Bauart Geprüft” Safety Directive: Safety Tests: CAN/CSA-C22.2 No950-93 UL 1950 EN 60950/06.
v Table of Contents DATA EXPRESS DE300i-S ..................................................................................................... 1 Packaging Materials ....................................................................................................... 1 Package Contents .......................................................................................................... 2 Serial Numbers ..................................................................................................
vi List of Figures Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure 1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13: A-1: B-1: B-2: B-3: C-1: D-1: D-2: Data Express DE300i-S Package Contents ........................................................ 1 DE300i-S Receiving Frame and Drive Carrier .................................................... 4 Receiving Frame Front Panel ................................................
Introduction 1 Data Express® DE300i-S Packaging Materials The Kingston Technology Data Express® system is shipped in a container designed to provide protection and prevent damage during shipment. The Data Express unit was carefully inspected before and during the packing procedure at the factory. Bent or broken connectors, or evidence of other damage to the Data Express should be reported to the shipper immediately. Refer to Figure 1 for the package contents.
2 Introduction If the wrong Data Express model has been received, please call Kingston's Storage Product Division at (800) 435-0642. A staff member will give you a Return Material Authorization (RMA) number to facilitate processing. Kingston cannot accept returns which do not display an RMA number on the outside of the package. Return the unit with all the original packing materials.
Introduction 3 Serial Numbers Both the Data Express receiving frame and carrier are labeled with serial numbers. These numbers must be reported to the Kingston Customer Service Representative in order to receive a Return Material Authorization (RMA) for warranty claims. Locate the serial number labels and record the numbers in the spaces provided below. Receiving Frame: Drive Carriers: DE300i-S User's Guide - Rev.
4 Introduction General Description The Kingston Technology Data Express® DE300i-S is a durable removable enclosure for three low-profile (1" high), 3.5" form factor SCSI drives. The DE300i-S is composed of a receiving frame with 8-bit single-ended SCSI connectors which contains three removable drive carriers and fits within 5.25" full-height peripheral slots.
Introduction • 5 Unit Number Indicator (Figures 3 and 4) - This LED displays the status of the drive carrier. A unit number is displayed when the carrier is installed and locked into the receiving frame or if the carrier is removed from the receiving frame. If the carrier is installed in the receiving frame but unlocked, a "u" will be displayed.
6 Introduction The Receiving Frame Rear Panel • I/O Connectors (J3, J4, and J5) - These connectors provide a standard interface for all SCSI signals (Figure 5). See Table 3 for pin assignments. • DC Power Connector (J6) - A standard 4-pin Molex power connector is used to accept DC power. • ID Select Connectors (J3A, J3B and J3C) - Pins 1 through 6 of these connectors provide SCSI unit ID selection for the computer system or expansion chassis.
Installation 7 DATA EXPRESS INSTALLATION Installing the Drives into the Carriers Preparation While performing the steps in this section, work on a soft surface to prevent excessive shock to the drive being installed. Also refer to the manufacturer's documentation provided with the drive. NOTE: A #2 Phillips screwdriver will be required during this procedure. 1. Remove the drive from its protective packaging. 2.
8 Installation Installation 1. Attach the I/O interface cable from the Data Express carrier board to the drive (Figure 6). 2. Attach the four-pin power cable from the carrier board to the drive (Figure 6). 3. Install the appropriate three-pin ID select cable into the carrier board connector (Figure 7). Refer to Figure 8 to decide which ID select cable to use. Figure 9 shows a typical drive with 2mm ID pins. Figure 10 shows a typical drive with 1.25mm ID pins. 4.
Installation 9 Signal Distribution Board Typical Drive ID Select Pins (Pins vary on each drive model. See Drive Manufacturer's Manual.) Data Express ID Select Interface (Inside Carrier) .1" (Upper) 2mm (Lower) Pin 1 ) D2 ) d (I ID1 ) Re wn ( (ID0 Bro Black DISK DRIVE ID Select Cable DATA EXPRESS CARRIER 0220A Disk Carrier Figure 7: Drive Carrier and SCSI ID Select Cable Connection DE300i-S User's Guide - Rev.
10 Installation Use This Connector 2mm Use This Connector .1 inch 2mm Data Express DE300 Carrier .1 inch 2mm 2mm .1 inch Data Express DE300 Carrier Cable PN 12-1000-0086 2mm If Drive Has This Connector Drive .1 inch Data Express DE300 Carrier Cable PN 12-1000-0086 Cable PN 12-1000-0085 .1 inch With This SCSI ID Cable With This SCSI ID Cable 2mm Use This Connector .1 inch .1 inch If Drive Has This Connector Drive With This SCSI ID Cable 1.25 mm 1.
Installation 11 TYPICAL 2MM DRIVE ID PIN CONFIGURATION Figure 9 illustrates a typical SCSI ID select connection to a drive with 2mm ID select pins. In most cases, the drive manufacturer labels each pair of SCSI ID select pins in their significant bit order (0, 1, 2 as shown in Figure 9). In other cases, the manufacturer does not label these pins in their significant bit order, but instead, assigns pin numbers only. In any case, all odd numbered pins or all even numbered pins will be the signal row.
12 Installation TYPICAL 1.25MM DRIVE ID PIN CONFIGURATION Figure 10 illustrates a typical SCSI ID select connection to a drive with 1.25mm ID select pins. Attach the .1 inch/1.25mm ID select cable to the drive using the 1.25mm connectors. Align the “ID0” pin with the black wire. Attach the other end of the ID select cable to the ID select connector located on the carrier board, inside the drive carrier. Refer to the manufacturer’s documentation to disable termination on the drive.
Installation 13 Installing the Receiving Frame The drive should be installed into the carrier before installing the receiving frame into the mounting bay of a computer or expansion chassis. NOTE: Use a #2 Phillips screwdriver during this procedure. 1. Turn off power to the computer. 2. Open the computer system according to the manufacturer’s instructions. If necessary, temporarily remove any expansion boards that may make installation difficult. 3.
14 Installation Table 2: J3A, J3B, J3C Option Pin Signal Descriptions PIN Signal Function 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 ID0 GND ID1 GND ID2 GND SCSI ID Ground SCSI ID Ground SCSI ID Ground Not Used Not Used Disable On Board Terminator Ground Remote LED Cathode Remote LED Anode Force Drive Fault Signal to Display Ground Drive Synchronization Signal Ground Terminate Power To/From SCSI Bus Ground Reserved Ground Disable Isolator Functions Disable Isolator Functions Kingston T
Installation 15 4. With the drive carriers locked into place inside the receiving frame, install the Data Express receiving frame into the drive opening in the computer or expansion chassis. Use the appropriate guides to position the Data Express, and fasten it into place with the four 6-32 x 1/4” screws provided. Figure 12 illustrates the location of the mounting holes. Mounting holes are provided on each side and the bottom of the receiving frame to accommodate a variety of mounting configurations.
16 Installation 9. Connect the power cable from the DC power supply in the computer or expansion chassis to the power connector on the Data Express receiving frame. Refer to Figure 5 for the Data Express receiving frame power connector location. 10. Replace any expansion boards that may have been removed earlier. Replace the system cover according to the manufacturer’s instructions. 11. Reconnect any system or peripheral cables removed earlier. 12.
Installation 2. 17 Unlock the Data Express carrier from the receiving frame. The unit number will begin flashing, indicating that the drive is spinning down. DO NOT REMOVE THE CARRIER FROM THE RECEIVING FRAME WHILE THE UNIT NUMBER IS FLASHING. The length of time that the unit number flashes is controlled by a small timing switch located on the side of the receiving frame. Refer to Appendix B for information on adjusting the timer (Figure B-3).
18 Installation SCSI Interface Connectors The SCSI interface connector pin assignments are supplied for your convenience. All odd numbered pins, except pins 25 and 29 must be connected to ground. Pin 25 should be left open. Pin 29 can be used for synchronized spindle operation. Pin 26 is reserved for terminator resistor power source.
Appendix A - Specifications/Dimensions 19 Appendices DE300i-S User's Guide - Rev.
20 Appendix A - Specifications/Dimensions Appendix A - Specifications/Dimensions SCSI Data Express subsystems conform to the Small Computer Systems Interface (SCSI) Standard set by the American National Standards Institute (ANSI).
Appendix A - Specifications/Dimensions 21 Receiving Frame with Carriers Installed 2.060 (52.3mm) 3.125 (79.2mm) 4.70 (11.9mm) 3.38 (85.9mm) 1.25 (31.8mm) 4.70 (11.9mm) .390 (9.9mm) 5.875 (149.2mm) #6-32 x 8 (Side) 8.150 (207.0mm) With Hot Swap Board DE300 .15 Board (3.8mm) Hot Swap Board 5.50 (139.7mm) .32 (8.1mm) 3.125 (79.2mm) #6-32 x 4 (Bottom) .64 (16.3mm) Carrier Only 1.070 (27.2mm) 4.665 (118.5mm) .25 (6.3mm) 7.38 (187.4mm) 3.750 (95.3mm) 1.750 (44.
22 Appendix B - Hot Swap Option Appendix B - Hot Swap Option The DE300i-S/H SCSI Hot Swap Board allows the installation, removal or exchange of Data Express carriers while your computer system is operating by monitoring and protecting the computer system and other peripheral devices on the SCSI Bus. The Hot Swap option eliminates the need to shut down your system when adding or removing a SCSI device by performing two functions: 1.
Appendix B - Hot Swap Option 23 Carriers Installed Hot Swap Board Remove Mounting Screws and use to Fasten Hot Swap Board (2 plcs) 0516A Stand Offs (Replace Motherboard Mounting Screws) Receiving Frame Motherboard Figure B-1: Installing the Hot Swap Board Jumper Options Most jumper options are configurable via the receiving frame motherboard (Figures 5 and 11). The Hot Swap Board provides three configurable jumpers, DTA, DTB, and DTC (Figure B-2).
24 Appendix B - Hot Swap Option I/O Connector Pin 1 DTA JP1 DRIVE A DRIVE B Disable On Board Termination Jumpers (Installed at Factory) JP2 DTB DRIVE C JP3 DTC Hot Swap Board (Installed) Carriers (Installed) 0518A Receiving Frame Motherboard Figure B-2: Hot Swap Board Termination Jumpers WARNING: Be careful not to remove or disturb the carrier unit at this point.
Appendix B - Hot Swap Option NOTE: 25 The timer for device spin down is controlled by a small selector, located in a cutout on the side of the Data Express receiving frame as shown in Figure B-3. When the key is turned to the off position, and when the timer receives a "No SCSI Activity" signal from the Hot Swap Board, it waits the specified delay time before displaying a “u” on the front panel of the receiving frame.
26 Appendix C - Attaching the On/Off Key Appendix C - Attaching the On/Off Key The following information will provide the necessary steps to attach the ON/OFF key to the key/lock mechanism so that it is non-removable. This configuration is preferred for some applications and is reversible. 1. Make certain power is off to the receiving frame. Access Hole Pawl Key/Lock Locate the rectangular shaped key/lock mechanism access hole on the inside of the receiving frame.
Appendix D - Optional Accessories 27 Appendix D - Optional Accessories Drive Carrier Remove This Piece of Foam 0524 DX300-DE-C Carrying Case Figure D-1: Optional Data Express Carrying Case The optional molded plastic carrying case is designed to transport the Data Express carrier from one location to another in a safe, impact and moisture resistant environment. Its compact dimensions, 7” long x 9” wide x 3.5” high, make it easy to carry and to store.
28 Appendix D - Optional Accessories 0221 Figure D-2: Optional Data Express DE300 Receiving Frame Brace If you bottom mount the receiving frame to your system or expansion chassis, you may wish to purchase the optional receiving frame brace. The receiving frame brace provides additional strength and rigidity to this unit. The receiving frame brace is usually not required for normal side mount installations. Kingston Technology Company DE300i-S User's Guide - Rev.
Reader's Comments 29 READER’S COMMENTS Please take a few moments when your computer system is up and running to send us your ideas and suggestions for improving our products and documentation.
Reader's Comments CUT ALONG THIS LINE FROM BOTTOM TO TOP OF PAGE 30 FOLD ALONG THIS LINE AND STAPLE SHUT NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES B U S I N E S S R E P LY M A I L FIRST CLASS MAIL PERMIT NO. 10686 SANTA ANA, CA POSTAGE WILL BE PAID BY ADDRESSEE TECHNOLOGY CORPORATION 17600 NEWHOPE STREET FOUNTAIN VALLEY CA 92708-9885 Kingston Technology Comapany DE300i-S User's Guide - Rev.