Instruction Manual

10 Installation
StorCase Technology, Inc. DE200i-SWCU2 User's Guide - Rev. A01
NOTE: Option pins 15-18 (Table 2) are used to remotely access the disk drive's
motor control options. Refer to the documentation provided by the drive
manufacturer for further information.
Table 1 - Option Pin Connector (W1) Signal Descriptions
DLYD_START RMT_START Function
Open Open Motor spins up on "Power On"
Open Closed Motor spins up only if SCSI
"Start" command is received
Closed Open Drive motor starts spinning up
approximately 12 seconds x the
SCSI ID number for each target
drive (12 second minimum)
Closed Closed Reserved
Closed = Jumper installed
Open = Jumper removed
Table 2 - Option Pins 15-18 Drive Motor Control
PIN Signal Function
1 ID0 SCSI ID
2 GND Ground
3 ID1 SCSI ID
4 GND Ground
5 ID2 SCSI ID
6 GND Ground
7 ID3 SCSI ID
8 GND Ground
9 RLEDC Remote LED Cathode
10 RLEDA Remote LED Anode
11 Reserved
12 Reserved
13 SYNC Drive Synchronous Signal
14 GND Ground
15 RMT_START Remote Start (see Table 2)
16 GND Ground
17 DLYD_START Delay Start (see Table 2)
18 GND Ground
19 DFAULT Force Drive Fault Signal to Display
20 GND Ground
21 WRTPT Force Drive Write Protect to Display
22 GND Ground