StorCase® Technology Data Express® DE200i-SWC160 Removable SCSI Ultra160 Drive Enclosure with 80-Pin SCA Interface User's Guide
i StorCase® Technology Data Express® DE200i-SWC160 Removable SCSI Ultra160 Drive Enclosure with 80-Pin SCA Interface User's Guide Part No. D89-0000-0133 B01 January 2003 StorCase Technology, Inc. 17600 Newhope Street Fountain Valley, CA 92708-9885 Phone (714) 438-1850 Fax (714) 438-1847 DE200i-SWC160 User's Guide - Rev. B01 StorCase Technology, Inc.
ii LIMITED WARRANTY STORCASE TECHNOLOGY, Incorporated (StorCase) warrants that its products will be free from defects in material and workmanship, subject to the conditions and limitations set forth below. StorCase will, at its option, either repair or replace any part of its product that proves defective by reason of improper workmanship or materials.
iii Free Technical Support StorCase provides free technical support. If you experience any difficulty during the installation or subsequent use of a StorCase product, please contact StorCases Technical Support Department prior to servicing your system. This warranty covers only repair or replacement of defective StorCase products, as described above. StorCase is not liable for, and does not cover under warranty, any costs associated with servicing and/or installation of StorCase products.
iv Declaration of Conformity Company Name: StorCase Technology, Inc.
v Table of Contents INTRODUCTION .................................................................................................................... Packaging Information .................................................................................................. Serial Numbers .............................................................................................................. Package Contents .................................................................................................
vi List of Figures Figure 1: Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9: Figure 10: Figure 11: Package Contents .......................................................................................... 2 DE200i-SWC160 Receiving Frame and Carrier ............................................. 3 Receiving Frame (Front View) ...................................................................... 4 Receiving Frame Unit ID Number and Activity Display ........................
Introduction 1 INTRODUCTION Packaging Information The StorCase Technology Data Express® system is shipped in a container designed to provide protection and prevent damage during shipment. The Data Express unit was carefully inspected before and during the packing procedure at the factory. Bent or broken connectors, or evidence of other damage to the Data Express should be reported to the shipper immediately. Refer to Figure 1 for the package contents.
2 Introduction Package Contents The DE200i-SWC160 package contents include the following items. If any item is missing or damaged, contact your StorCase dealer for a replacement. Da ta E xpr ess I/O ID Driv e Carr Sele ier Disk (Not Driv Inclu e ded) Pow er Cab le le Cab Cove (Pro r le vide d) Cab ct Cab le Driv Hard e Phill 3/16 ips wareMounting Flat # 6-32(4ea HD x ) 0151 Cab Scre le # Flat 6-32 ws (2Cove HD x 3/16plcsr ) 0430h 7 8 1. #6-32 x 1/4 Phillips Pan Head Mounting Screws 2.
Introduction 3 General Description The StorCase Technology Data Express® DE200i-SWC160 is composed of a receiving frame which supports SCSI Ultra160 interfaces and fits within a 5.25" half-height peripheral slot. This 16-bit I/O can support up to 160MByte/sec transfer rates. The receiving frame contains one (1) removable drive carrier designed to provide durable and reliable mounting for one (1) 3.5" form factor Single Connector Attachment (SCA) SCSI drive (Figure 2).
4 Introduction Receiving Frame (Front) (Figure 3) The Key Lock/Drive Power Switch performs three functions. The key lock assures proper seating of the device carrier within the receiving frame, turns power to the device carrier on and off, and prevents unauthorized removal or installation of the carrier. For the computer to access data on the drive, the key must be turned counterclockwise to the locked position. The key can be permanently attached to the locking mechanism as shown in Appendix C.
Introduction 5 Carrier Removed from Receiving Frame Carrier Installed (unlocked) Carrier Installed (locked) Activity Indicator 0064c Fan Failure The number "2" shown above is for illustration purposes only. It can be any valid unit ID number. The letter "u" and F will appear as illustrated. Figure 4: Receiving Frame Unit ID Number and Activity Display Receiving Frame (Rear) (Figure 5) DC Power Connector (P1): The DE200i-SWC160 uses a standard 4-pin DC power connector to accept DC power.
6 Introduction Fan Fault LED/Alarm Temporary Disable Jumper Option (Pins 17 & 18): No Jumper (Factory Default) - Fan Fault LED and Alarm will both function when either fan fails. Jumper on Pins 17 & 18- Jumper (provided) installed will temporarily disable both Fan Fault LED and Alarm in the event of a single fan failure. Fan Fault LED and Alarm will still function should the second fan fail.
Introduction 7 68-Pin I/O Connector (J2) DC Power Connector (P1) Buzzer P1 J3 J3 Jumpers (Factory-Installed on Pins 7 & 8 and Pins 9 & 10 Do Not Remove!) Option Pin Connector (W1) J4 0456c J4 Jumper (Factory-Installed Do Not Remove!) Factory-Installed Jumpers (Do Not Remove!) 9 10 17 19 21 18 20 22 Fan Fault LED/Alarm Temporary Disable Jumper Option Figure 5: Receiving Frame Motherboard (Rear View) DE200i-SWC160 User's Guide - Rev. B01 StorCase Technology, Inc.
8 Installation INSTALLATION Installing the Drive in the Carrier Preparation While performing the steps in this section, work on a soft surface to prevent excessive shock to the drive being installed. Also refer to the manufacturer's documentation provided with the drive. NOTE: A #2 Phillips screwdriver will be required during this procedure. 1. Remove the drive from its protective packaging. 2. Plastic Drive Bezel: If the drive came equipped with a plastic front bezel, it must be removed. 3.
Installation 9 Drive (Not Included) Drive Carrier Board Drive Carrier 0151e #6-32 x 1/4 Phillips Flat Head Screw (4 each) Figure 6: Drive Installation Assembly 1 Insert this end into the carrier first 2 Slide the cover towards the back of the carrier 0823a 3 Secure with two (2) #6-32x1/4 Phillips Flat Head screws. Figure 7: Drive Cover Installation DE200i-SWC160 User's Guide - Rev. B01 StorCase Technology, Inc.
10 Installation Installing the Receiving Frame The drive should be installed into the carrier before installing the receiving frame into the mounting bay of a computer or expansion chassis. A #2 Phillips screwdriver will be required for installation. 1. Turn OFF power to the computer. 2. Open the computer system according to the manufacturers instructions. If necessary, temporarily remove any expansion boards that may make installation difficult. 3.
Installation 11 Table 1: Option Pin Connector (W1) Signal Descriptions PIN Signal Function 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 ID0 GND ID1 GND ID2 GND ID3 GND FFAULT FFAULT SYNC GND RMST GND DYST GND DISABLE DISABLE FAN1 FAN1 FAN2 FAN2 SCSI ID Ground SCSI ID Ground SCSI ID Ground SCSI ID Ground Fan Failure LED/Alarm Enable Fan Failure LED/Alarm Enable Drive Synchronous Signal Ground Remote Start (see Table 3) Ground Delay Start (see Table 3) Ground FFAULT/Alarm Temporary Disable F
12 Installation Table 2: Option Pins 13-16 Drive Motor Control DYST RMST Open Open Open Closed Closed Open Closed Closed Function Motor spins up on "Power On" Motor spins up only if SCSI "Start" command is received Drive motor starts spinning up approximately 12 seconds x the SCSI ID number for each target drive (12 second minimum) Reserved Closed = Jumper installed Open = Jumper removed NOTE: Option Pins 13-16 (Table 2) are used to remotely access the disk drive's motor control options.
Installation 13 4. With the drive carrier locked into place inside the receiving frame, install the DE200i-SWC160 receiving frame into the drive bay in the computer or expansion chassis. Use the appropriate guides to position the DE200i-SWC160, and fasten it into place with the four (4) #6-32 Phillips screws provided. Figure 9 illustrates the location of the mounting holes. Mounting holes are provided on each side and the bottom of the receiving frame to accommodate a variety of mounting configurations.
14 Installation 7. Connect the power cable from the DC power supply in the computer or expansion chassis to the power connector on the DE200i-SWC160 receiving frame. Refer to Figure 5 for the receiving frame power connector location. 8. Replace any expansion boards that may have been removed earlier. Replace the system cover according to the manufacturers instructions. 9. Reconnect any system or peripheral cables removed earlier. 10. Turn ON power to the computer.
Installation 15 5. The new drive may need to be formatted or initialized prior to use with the operating system and applications software. Refer to the drive and computer manufacturer's documentation for formatting information. Unit ID Number Display ID Select Rotating Switch 0179f Figure 10: Unit ID Select Switch Location DE200i-SWC160 User's Guide - Rev. B01 StorCase Technology, Inc.
16 Installation Adjusting the Spin Down/Up Timer NOTE: The timer for device spin down is controlled by a small selector, located in a cutout on the side of the DE200i-SWC160 receiving frame as shown in Figure 11. The amount of time required for a drive to spin down is approximately 15 seconds or more. This number can vary depending on the type of SCSI device and manufacturer (some drives may require 45 seconds or more). The factory configuration is set for 20 seconds.
Appendix A - Specifications/Dimensions 17 APPENDICES DE200i-SWC160 User's Guide - Rev. B01 StorCase Technology, Inc.
18 Appendix A - Specifications/Dimensions Appendix A - Specifications/Dimensions SCSI Data Express subsystems conform to the Small Computer Systems Interface (SCSI) Standard set by the American National Standards Institute (ANSI).
Appendix A - Specifications/Dimensions 19 Hot Swap/ Repeater Isolator Board 373u Figure A-1: DE200i-SWC160 Physical Dimensions (Dimensions are for reference only) DE200i-SWC160 User's Guide - Rev. B01 StorCase Technology, Inc.
20 Appendix B - Factory-Installed Options Appendix B - Factory-Installed Options DX1/200-SWC160/RH Ultra160 Isolator Board The DE200i-SWC160 Isolator Board (Figure B-1) is an upgrade attachment for the DE200i-SWC160 receiving frame. This attachment provides a bus-isolating feature as described below.
Appendix B - Factory-Installed Options 2. 21 Remove the two (2) screws on the receiving frame motherboard. NOTE: Save these screws for Step 5! 3. Attach two (2) stand-offs (included) to the mounting holes on the receiving frame motherboard (Figure B-3). 4. Carefully align the connectors of the Isolator Board with the connectors on the receiving frame motherboard and gently push the board into position. Make certain that all connectors are properly mated. 5.
22 Appendix B - Factory-Installed Options J4 Jumper (Factory Installed Do Not Remove) J4 J3 456b DE100 or DE200 (Ultra160 Only) Receiving Frame Motherboard Remove Jumpers on J3 Pins 7 & 8 and 9 & 10 Before Installing Isolator Board Figure B-2: J3 Jumpers DE100 or DE200 (Ultra160 Only) Receiving Frame Motherboard Receiving Frame Stand-Offs (2 per Isolator Board) 0452b I/O Connector #6-32 x 1/4 Phillips Pan Head Screws DX1/200-SWC160/RH Isolator Board Figure B-3: Attaching the Isolator Board Sto
Appendix B - Factory-Installed Options 23 Using the Isolator Board Carrier Removal Follow the procedures below to remove the DE200i-SWC160 carrier from the receiving frame equipped with the Isolator Board. 1. Verify that the drive is not active. If the system is on a network, make certain other users are not accessing the target drive, then disable it from the network. Dismount the drive. 2. Turn the DE200 key lock mechanism (located on the front of the receiving frame), clockwise to the OFF position.
24 Appendix B - Factory-Installed Options Solenoid Drive Lock The factory-installed solenoid option prevents premature removal of the carrier and drive unit until the target drive has fully spun down. For most disk drives, this period of time can range from 15-40 seconds, depending on the type of drive being used (e.g. Seagate Barracuda drives require up to 45 seconds). Refer to the drive manufacturer's documentation for specific drive information.
Appendix C - Attaching the ON/OFF Key 25 Appendix C - Attaching the ON/OFF Key The following information describes the necessary steps to attach the ON/OFF key to the key lock mechanism so that it is non-removable, preventing accidental key loss. The procedure can be reversed at a later date to revert back to a removable key. 1. Make certain power is OFF to the receiving frame. Locate the rectangular-shaped key lock mechanism access hole on the inside of the receiving frame.
26 Appendix D - Field-Replacing the Carrier Fans Appendix D - Field-Replacing the Carrier Fans Fan 2 Fan 1 Power Cables Fan Bracket Drive Carrier 0179g #6-32 Phillips Flat Head Screw (3 Places) Figure D-1: Removing the Fan Bracket from the Carrier The DE200i-SWC160 drive carrier contains two (2) front-mounted drive carrier fans for enhanced heat dissipation.
Appendix D - Field-Replacing the Carrier Fans 27 Fan Fan Bracket 0826 Phillips Head Screws (4 per Fan) Figure D-2: Replacing the Fan 1. Carefully uninstall drive (if still installed in carrier). Refer to section "DE200i-SWC160 INSTALLATION" for further information. 2. To remove fan(s) to be replaced, loosen and remove the three (3) #6-32 Phillips Flat Hd. screws securing the fan bracket to the drive carrier (Figure D-1). 3.
28 Appendix E - Optional Accessories Appendix E - Optional Accessories Carrying Case Drive Carrier (Not Included) 0460c Figure E-1: Carrying Case The optional molded plastic carrying case (P/N DX100-DE-C) is designed to transport the DE200i-SWC160 carrier from one site to another in a safe, impact and moisture resistant environment. Its compact dimensions, 7 long x 9 wide x 4 high, make it easy to carry and to store.
29 Reader's Comments Reader's Comments Please take a few moments when your computer system is up and running to send us your ideas and suggestions for improving our products and documentation.
CUT ALONG THIS LINE FROM BOTTOM TO TOP OF PAGE FOLD ALONG THIS LINE AND STAPLE SHUT NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES B U S I N E S S R E P LY M A I L FIRST CLASS MAIL PERMIT NO. 10686 SANTA ANA, CA POSTAGE WILL BE PAID BY ADDRESSEE TECHNOLOGY CORPORATION 17600 NEWHOPE STREET FOUNTAIN VALLEY CA 92708-9885 DE200i-SWC160 User's Guide - Rev. B01 StorCase Technology, Inc.