User guide

10 Installation
StorCase Technology, Inc. DE100i-SWC160 User's Guide - Rev. D01
NOTE: Option Pins 13-16 (Table 2) are used to remotely access the disk drive's motor
control options. Refer to the documentation provided by the drive manufacturer for
further information.
Open Open Motor spins up on "Power On"
Open Closed Motor spins up only if SCSI
"Start" command is received
Closed Open Drive motor starts spinning up
approximately 12 seconds x the
SCSI ID number for each target
drive (12 second minimum)
Closed Closed Reserved
Closed = Jumper installed
Open = Jumper removed
DYST RMST Function
1 ID0 SCSI ID
2 GND Ground
3 ID1 SCSI ID
4 GND Ground
5 ID2 SCSI ID
6 GND Ground
7 ID3 SCSI ID
8 GND Ground
9 FFAULT Fan Fault LED/Alarm Enable
10 FFAULT Fan Fault LED/Alarm Enable
11 SYNC Drive Synchronous Signal
12 GND Ground
13 RMST Remote Start (see Table 3)
14 GND Ground
15 DYST Delay Start (see Table 3)
16 GND Ground
17 Reserved Reserved (Do Not Remove Jumper!)
18 Reserved Reserved (Do Not Remove Jumper!)
19 FAN1 Fan 1 Power Enable
20 FAN1 Fan 1 Power Enable
21 Reserved Reserved
22 Reserved Reserved
PIN Signal Function
Table 1: Option Pin Connector (W1) Signal Descriptions
Table 2: Option Pins 13-16 Drive Motor Control
NOTE: Table 1 applies to DE100i-SWC160 receiving frames Rev. B00 or higher only. Refer
to Appendix F for further information.