User's Guide switch DE100i-SW, DE100i-SWC

StorCase Technology, Inc. DE100i-SW/SWC User's Guide - Rev. G01
14 Installation
Front of
Receiving
Frame
0143
0
2
4
6
8
A
C
E
0 = 10 SECONDS 8 = 50 SECONDS
1 = 15 SECONDS 9 = 55 SECONDS
2 = 20 SECONDS A = 60 SECONDS
3 = 25 SECONDS B = 65 SECONDS
4 = 30 SECONDS C = 70 SECONDS
5 = 35 SECONDS D = 75 SECONDS
6 = 40 SECONDS E = 80 SECONDS
7 = 45 SECONDS F = 85 SECONDS
Spin Down/Up Time
Figure 11: Device Spin Down/Up Timer
NOTE: The timer for device spin down is controlled by a small selector, located in a cutout
on the side of the DE100 receiving frame as shown in Figure 11. When the key
is turned to the OFF position, and when the timer receives a No SCSI Activity signal
from the Hot Swap Board, it waits the specified delay time before displaying a u
on the front panel of the receiving frame. The amount of time required for a disk
drive to spin down is approximately 15 seconds or more. This number can vary
depending on the type of SCSI device and manufacturer (e.g. a Seagate Barracuda
may require 45 seconds). The factory configuration is set for 20 seconds. A
different delay time may be selected with the provided aligment tool. Refer to the
SCSI device manufacturers manual for more information on required device spin
down time.
Adjusting the Spin Down/Up Timer