Data Silo DS100 User's Guide

20 Appendix A - Specifications/Dimensions
StorCase Technology, Inc. DS100 (U320) User's Guide - Rev. A02
Environmental Specifications
Operating Storage
Ambient Temperature C to 40° C -40° C to 70° C
Relative Humidity
( 1 )
10% to 80% 10% to 90%
Altitude -1000 to 10,000 ft -1000 to 40,000 ft
-305m to 3048m -305m to 12195m
Shock
(2)
10g 60g
(1)
Non-condensing with maximum gradient of 10% per hour.
(2)
11 msec pulse width 1/2 sine wave.
The following Data Silo DS100 specifications and dimensions are provided for reference only.
Chassis Reliability/Maintainability DS100 Fan Air Flow (Maximum)
MTBF 500,000 Hours 1-Bay 2-Bay 4-Bay
MTTR 5 Minutes 17 CFM 36 CFM 72 CFM
Preventive None (60mm, 1ea.) (80mm, 1ea.) (80mm, 2ea.)
Maintenance
Electrical DS100 1-Bay DS100 2-Bay DS100 4-Bay
Input 90-260 VAC, Auto 90-260 VAC, Auto 90-260 VAC, Auto
Select, 47-60Hz Select, 47-60Hz Select, 47-60Hz
DC Output
(Continuous) 40 watts 65 watts 130 watts
DC Output (Peak ) 60 watts 135 watts 270 watts
Physical
Specifications DS100 1-Bay DS100 2-Bay DS100 4-Bay
Height 2.70" (68.6mm) 4.28" (108.7mm) 10.27" (260.8mm)
Width 9.50" (241.3mm) 9.50" (241.3mm) 7.54" (191.5mm)
Depth 11.35" (288.3mm) 11.35" (288.3mm) 11.35" (288.3mm)
Drive Mounting 9.75" (247.7mm) 9.75" (247.7mm) 9.75" (247.7mm)
Depth
Actual Weight 6.4lb. (2.91kg) 8.2lb (3.73kg) 18.6lb (8.45kg)
Appendix A - Specifications/Dimensions