User Manual
InfoStation 12-bay JBOD User's Guide - Rev. A00 StorCase Technology, Inc.
JBOD Controller Configuration 25
Table 4: Terminal Program Communications Parameters
Set the communications parameters as follows:
Figure 10: Monitor Utility Screen
To start the Monitor Utility from the remote terminal (or terminal emulation program), press
Ctrl-D. This will invoke the Monitor Utility (Figure 10).
At the top of the screen is the Model Number and Firmware version of the JBOD Controller.
At the left, is the "LCD Display" window. The information displayed here also appears on the
front LCD display. Below is the "Menu" window with the Main Menu options. To the right is
the "OUTPUT" window that shows more detailed information about the JBOD Controller. At
the bottom of the screen is the navigation legend.
Setting
Value
Baud Rate
Data Bits
Stop Bits
Parity
Flow Control
2400, 4800, 9600, 14400, 19200,
28800, 38400, 57600, 115200
7, 8
1, 2
None, Odd, Even
Software Flow Control (XON/XOFF)
Default Value
115200
8
1
None
Enabled










