User's Manual

Table Of Contents
91
unnecessary errors in the results.
Operation
Interface
In {Setting}press [4]4.EDMto enter
{EDM Setting}. Press [★] in the
measurement related interfaces then
select 2.EDM Set also can enter
{EDM Setting}.
Use [] [] to highlight a item then
use [ ] [ ] to toggle the options
available.
Press [F3] OK to confirm the
settings.
Refl.Type: Set the type of target on distance measuring.
Prism : The target is reflector prism.
Tape : The target is reflector tape.
NonPrism : The target is object itself, i.e., reflectless.
EDM Mode: Set the mode of EDM working.
Standard : Fine mode, default high precision mode.
Fast : Fast mode with increased measurement speed but possibly slightly
reduced accuracy.
Track : Continuous measuring mode.
Repeat : Repeat measuring until manually stop.
Average : After measuring defined times on standard mode, average the
results.
Constant: Input the prism constant whenRefl.Typeis Prism.
The unit is mm and input range from -999.9 to 999.9.
Pointer: To emit a laser beam coaxial to the telescope, creat a visible
red spot on the near target to indicate the current aiming point position
OFF/ON