Datasheet

Application information VNQ5160K-E
20/30 Doc ID 13349 Rev 7
1. No false open-load indication when load is connected: in this case we have to avoid
V
OUT
to be higher than V
Olmin
; this results in the following condition:
V
OUT
=(V
PU
/(R
L
+R
PU
))R
L
<V
Olmin.
2. No misdetection when the load is disconnected: in this case the V
OUT
has to be higher
than V
OLmax
; this results in the following condition:
R
PU
<(V
PU–
V
OLmax
)/I
L(off2)
.
Because I
s(OFF)
may significantly increase if V
out
is pulled high (up to several mA), the pull-
up resistor R
PU
should be connected to a supply that is switched OFF when the module is in
standby.
The values of V
OLmin
, V
OLmax
and I
L(off2)
are available in the Electrical characteristics
section.
Figure 28. Open-load detection in off-state
VOL
V batt. VPU
R
PU
RL
R
DRIVER
+
LOGIC
+
-
INPUT
STATUS
V
CC
OUT
GROUND
I