Datasheet

Electrical specifications VNQ5160K-E
10/30 Doc ID 13349 Rev 7
V
DEMAG
Turn-off output voltage
clamp
I
OUT
=1A; V
IN
=0; L=20mH V
CC
-41 V
CC
-46 V
CC
-52 V
V
ON
Output voltage drop
limitation
I
OUT
=0.03A (see Figure 5.)
T
j
= -40°C...+150°C
25 mV
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles
Table 10. Open-load detection
Symbol Parameter Test conditions Min Typ Max Unit
I
OL
Open-load on-state
detection threshold
V
IN
= 5V ,8V<V
CC
<18V 10
See
Figure
18.
40 mA
t
DOL(on)
Open-load on-state
detection delay
I
OUT
= 0A, V
CC
=13V
(See Figure 4.)
200 s
t
POL
Delay between INPUT
falling edge and
STATUS rising edge in
Open-load condition
I
OUT
= 0A (See Figure 4.) 200 500 1000 s
V
OL
Open-load OFF-state
voltage detection
threshold
V
IN
= 0V, 8V<V
CC
<16V 2
See
Figure
19.
4V
t
DSTKON
Output short circuit to
V
cc
detection delay at
turn-off
(See Figure 4.)180t
POL
s
Table 11. Logic input
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Input low level 0.9 V
I
IL
Low level input current V
IN
= 0.9V 1 A
V
IH
Input high level 2.1 V
I
IH
High level input current V
IN
= 2.1V 10 A
V
I(hyst)
Input hysteresis voltage 0.25 V
V
ICL
Input clamp voltage
I
IN
= 1mA
I
IN
= -1mA
5.5
-0.7
7V
V
V
SDL
STAT_DIS low level
voltage
0.9 V
I
SDL
Low level STAT_DIS
current
V
SD
=0.9V 1 A
V
SDH
STAT_DIS high level
voltage
2.1 V
Table 9. Protection
(1)
(continued)
Symbol Parameter Test conditions Min. Typ. Max. Unit