Datasheet
Electrical specifications VNQ5050K-E
14/31 Doc ID 10864 Rev 7
4 -6 V -7 V 1 pulse
100 ms, 0.01
Ω
5b
(2)
+65 V +87 V 1 pulse 400 ms, 2
Ω
Table 14. Electrical transient requirements (part 2/3)
ISO 7637-2:
2004(E)
test pulse
Test level results
(1)
III IV
1C C
2a C C
3a C C
3b C C
4C C
5b
(2)
CC
1. The above test levels must be considered referred to V
CC
= 13.5V except for pulse 5b
2. Valid in case of external load dump clamp: 40V maximum referred to ground.
Table 15. Electrical transient requirements (part 3/3)
Class Contents
C All functions of the device are performed as designed after exposure to disturbance.
E
One or more functions of the device are not performed as designed after exposure
to disturbance and cannot be returned to proper operation without replacing the
device.
Table 13. Electrical transient requirements (part 1/3) (continued)
ISO 7637-2:
2004(E)
test Pulse
Test levels
(1)
Number of
pulses or
test times
Burst cycle/pulse
repetition time
Delays and
impedance
III IV