Datasheet
Electrical specifications VNQ5050K-E
10/31 Doc ID 10864 Rev 7
Note: To ensure long term reliability under heavy overload or short circuit conditions, protection
and related diagnostic signals must be used together with a proper software strategy. If the
device is subjected to abnormal conditions, this software must limit the duration and number
of activation cycles
Table 8. Status pin (V
SD
=0)
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
STAT
Status low output
voltage
I
STAT
= 1.6 mA, V
SD
=0V 0.5 V
I
LSTAT
Status leakage current
Normal operation or V
SD
=5V,
V
STAT
= 5V
10 μA
C
STAT
Status pin input
capacitance
Normal operation or V
SD
=5V,
V
STAT
= 5V
100 pF
V
SCL
Status clamp voltage
I
STAT
= 1mA
I
STAT
= - 1mA
5.5
-0.7
7V
V
Table 9. Protections
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC short circuit
current
V
CC
=13V
5V<V
CC
<36V
13.5 19 26.5
26.5
A
A
I
limL
Short circuit current
during thermal cycling
V
CC
=13V
T
R
<T
j
<T
TSD
7A
T
TSD
Shutdown
temperature
150 175 200 °C
T
R
Reset temperature
T
RS
+ 1
T
RS
+ 5
°C
T
RS
Thermal reset of
STATUS
135 °C
T
HYST
Thermal hysteresis
(T
TSD
-T
R
)
7°C
t
SDL
Status delay in
overload conditions
T
j
>T
TSD
(See Figure 4)20μs
V
DEMAG
Turn-off output voltage
clamp
I
OUT
=2A; V
IN
=0; L=6mH
V
CC
-41
V
CC
-46
V
CC
-52
V
V
ON
Output voltage drop
limitation
I
OUT
=0.1A (see Figure 5)
T
j
= -40°C...+150°C
25 mV
Table 10. Open-load detection
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
OL
Open-load on-state
detection threshold
V
IN
= 5V, 8V<Vcc<18V
(See Figure 22.)
10 70 mA
t
DOL(on)
Open-load on-state
detection delay
I
OUT
= 0A, V
CC
=13V
(See Figure 4.)
200 μs