Datasheet

VNN7NV04P-E, VNS7NV04P-E Protection features
Doc ID 15632 Rev 4 17/29
3.3 SOT-223 maximum demagnetization energy
Figure 32. SOT-223 maximum turn-off current versus load inductance
Legend
A = Single Pulse at T
Jstart
= 150 °C
B = Repetitive pulse at T
Jstart
= 100 °C
C = Repetitive Pulse at T
Jstart
= 125 °C
Conditions:
V
CC
=13.5V
Values are generated with R
L
=0Ω. In case of repetitive pulses, T
jstart
(at beginning of each
demagnetization) of every pulse must not exceed the temperature specified above for
curves B and C.
Figure 33. SOT-223 demagnetization
1
10
100
0.01 0.1 1 10
L(mH)
I
LMAX (A)
V
IN
, I
L
t
Demagnetization
Demagnetization
Demagnetization