Datasheet

Table Of Contents
VNH7013XP-E Package and PCB thermal data
Doc ID 022370 Rev 3 19/24
Figure 17. Thermal fitting model of an H-bridge in PowerSSO-36
Table 15. Thermal parameters
(1)
1. The blank space means that the value is the same as the previous one.
Area/island (cm
2
) Footprint 2 8 4L
R1 = R7 (°C/W) 0.2
R2 = R8 (°C/W) 1.6
R3 (°C/W) 8
R4 (°C/W) 30 16 16 10
R5 (°C/W) 40 22 12 5
R6 (°C/W) 36 28 10 6
R9 = R15 (°C/W) 0.1
R10 = R16 (°C/W) 2.8
R11 = R17 (°C/W) 22 14 14 14
R12 = R18 (°C/W) 49 30 30 20
R13 = R19 (°C/W) 52 36 28 16
R14 = R20 (°C/W) 50 32 26 18
R21 = R22 (°C/W) 80 60 50 40
R23 (°C/W) 80 50 45 30
C1 = C7 = C9 = C15 (W.s/°C) 0.001
C2 = C8 (W.s/°C) 0.009
C3 (W.s/°C) 0.09
C4 (W.s/°C) 0.5 0.8 0.8 0.8
C5 (W.s/°C) 0.8 1.4 2 3
C6 (W.s/°C) 5 6 8 10
C10 = C16 (W.s/°C) 0.1
C11 = C17 (W.s/°C) 0.07
C12 = C18 (W.s/°C) 0.45 0.45 0.45 0.6
C13 = C19 (W.s/°C) 0.8 1 1.2 2.5
C14 = C20 (W.s/°C) 4 5 6 8
C21 = C22 = C23 (W.s/°C) 0.01 0.006 0.005 0.005