Datasheet

VNN7NV04, VNS7NV04, VND7NV04, VND7NV04-1 Protection features
Doc ID 7383 Rev 4 17/37
3.2 SO-8 maximum demagnetization energy
Figure 30. SO-8 maximum turn-off current versus load inductance
Legend
A = Single Pulse at T
Jstart
=150 °C
B = Repetitive pulse at T
Jstart
=100 °C
C = Repetitive Pulse at T
Jstart
=125 °C
Conditions:
V
CC
=13.5 V
Values are generated with R
L
=0 Ω. In case of repetitive pulses, T
jstart
(at beginning of each
demagnetization) of every pulse must not exceed the temperature specified above for
curves B and C.
Figure 31. SO-8 demagnetization
1
10
100
0.1 1 10 100
L(mH)
I
LMAX (A)
A
B
C
V
IN
, I
L
t
Demagnetization
Demagnetization
Demagnetization