Datasheet

VND5T100AJ-E Electrical specifications
Doc ID 018513 Rev 2 9/32
2.3 Electrical characteristics
8V<V
CC
<36V; -4C<T
j
< 150 °C, unless otherwise specified.
.
Table 5. Power section
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
CC
Operating supply voltage 8 24 36 V
V
USD
Undervoltage shutdown 3.5 5 V
V
USDhyst
Undervoltage shutdown
hysteresis
0.5 V
R
ON
On-state resistance
(1)
1. For each channel.
I
OUT
=1.5A; T
j
=2C 100
m
I
OUT
=1.5A; T
j
= 150 °C 200
V
clamp
Clamp voltage I
S
=20mA 58 64 70 V
I
S
Supply current
Off-state: V
CC
=24V; T
j
=2C;
V
IN
=V
OUT
=V
SENSE
=0V
2
(2)
2. PowerMos leakage included
5
(2)
µA
On-state: V
CC
=24V; V
IN
=5V;
I
OUT
=0A
4.2 6 mA
I
L(off)
Off-state output current
V
IN
=V
OUT
=0V; V
CC
=24V;
T
j
=2C
00.01 3
µA
V
IN
=V
OUT
=0V; V
CC
=24V;
T
j
=12C
05
V
F
Output - V
CC
diode voltage -I
OUT
= 1.5A; T
j
= 150 °C 0.7 V
Table 6. Switching
(1)
1. Operating conditions: V
CC
=24V; T
j
=2C
Symbol Parameter Test conditions Min. Typ. Max. Unit
t
d(on)
Turn-on delay time R
L
=16 27 µs
t
d(off)
Turn-off delay time R
L
=16 38 µs
dV
OUT
/dt
(on)
Turn-on voltage slope R
L
=16 1Vµs
dV
OUT
/dt
(off)
Turn-off voltage slope R
L
=16 0.65 Vµs
W
ON
Switching energy losses
during t
won
R
L
=16 0.23 mJ
W
OFF
Switching energy losses
during t
woff
R
L