Datasheet
VND5T100AJ-E Electrical specifications
Doc ID 018513 Rev 2 17/32
Table 11. Truth table
Conditions Fault reset standby Input Output Sense
Standby L L L 0
Normal operation
X
X
L
H
L
H
0
Nominal
Overload
X
X
L
H
L
H
0
> Nominal
Overtemperature / short to ground
X
L
H
L
H
H
L
Cycling
Latched
0
V
SENSEH
V
SENSEH
Undervoltage X X L 0
Short to V
BAT
L
H
X
L
L
H
H
H
H
0
V
SENSEH
< Nominal
Open-load off-state (with pull-up)
L
H
X
L
L
H
H
H
H
0
V
SENSEH
0
Negative output voltage clamp X L Negative 0