Datasheet
Electrical specifications VND5T050AK-E
8/32 Doc ID 022694 Rev. 3
2.2 Thermal data
L
smax
Maximum strain inductance in short circuit condition
R
L
=300mΩ, V
batt
=32V, T
jstart
=150°C, l
out
=I
LMHmax
40 µH
V
ESD
Electrostatic discharge
(Human Body Model: R = 1.5 KΩ; C = 100 pF)
–IN
1,2
–CS
1,2
–FR_Stby
–OUT
1,2
–V
CC
4000
2000
4000
5000
5000
V
V
V
V
V
V
ESD
Charge device model (CDM-AEC-Q100-011) 750 V
T
j
Junction operating temperature -40 to 150 °C
T
stg
Storage temperature -55 to 150 °C
Table 3. Absolute maximum ratings (continued)
Symbol Parameter Value Unit
Table 4. Thermal data
Symbol Parameter Value Unit
R
thj-case
Thermal resistance junction-case (max.) (with one channel ON) 2 °C/W
R
thj-amb
Thermal resistance junction-ambient (max.)
See
Figure 27
°C/W