Datasheet

Table Of Contents
Electrical specifications VND5T035AK-E
10/31 Doc ID 018942 Rev 5
Figure 4. Treset definition
Table 7. Logic inputs
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Input low level voltage 0.9 V
I
IL
Low level input current V
IN
= 0.9 V 1 µA
V
IH
Input high level voltage 2.1 V
I
IH
High level input current V
IN
= 2.1 V 10 µA
V
I(hyst)
Input hysteresis voltage 0.25 V
V
ICL
Input clamp voltage
I
IN
= 1 mA 5.5 7 V
I
IN
= -1 mA -0.7 V
V
FR_Stby_L
Fault_reset_standby low
level voltage
0.9 V
I
FR_Stby_L
Low level
fault_reset_standby current
V
FR_Stby
= 0.9 V 1 µA
V
FR_Stby_H
Fault_reset_standby high
level voltage
2.1 V
I
FR_Stby_H
High level
fault_reset_standby current
V
FR_Stby
= 2.1 V 10 µA
V
FR_Stby
(hyst)
Fault_reset_standby
hysteresis voltage
0.25 V
V
FR_Stby_CL
Fault_reset_standby clamp
voltage
I
FR_Stby
= 15 mA (10 ms) 11 15 V
I
FR_Stby
= -1 mA -0.7 V
t
reset
Overload latch-off reset time See Figure 4 224µs
t
stby
Standby delay See Figure 5 120 1200 µs
7BUHVHW
)5B67%<
,1
287387
&6
2YHUORDG
&KDQQHO
*$3*&)7