Datasheet
VND5T016ASP-E Electrical specifications
Doc ID 022687 Rev. 3 17/31
Figure 12. Device behavior in overload condition
)$8/7B5(6(7
,1
Q
287387
Q
&6
Q
29(5/2$'
&+$11(/
Q
9
VHQVH+
RYHUORDG
RYHUORDGUHVHW
RYHUORDGGLDJUHVHW
WBUHVHW
WBUHVHW
*$3*&)7
287387
Q
DQG&6
Q
FRQWUROOHGE\,1Q
)$8/7B5(6(7IURPµ¶WRµ¶ĺQRDFWLRQRQ&6
Q
SLQ
RYHUORDGODWFKRII,QQKLJKĺ&6
Q
KLJK
)$8/7B5(6(7ORZ$1'7HPSFKDQQHOQRYHUORDGBUHVHWĺRYHUORDGODWFKUHVHWDIWHUWBUHVHW
WR)$8/7B5(6(7ORZ$1',1
Q
KLJKĺWKHUPDOF\FOLQJ&6
Q
KLJK
)$8/7B5(6(7KLJKĺODWFKRIIUHVHWGLVDEOHG
WRRYHUORDGHYHQWDQG)$8/7B5(6(7KLJKĺODWFKRIIQRWKHUPDOF\FOLQJ
WRRYHUORDGGLDJQRVWLFGLVDEOHGHQDEOHGE\WKHLQSXW
RYHUORDGODWFKRIIUHVHWE\)$8/7B5(6(7
29(5/2$' WKHUPDOVKXWGRZQ25SRZHUOLPLWDWLRQ
Table 11. Truth table
Conditions
Fault reset
standby
Input Output Sense
Standby L L X 0
Normal operation
X
X
L
H
L
H
0
Nominal
Overload
X
X
L
H
L
H
0
> Nominal
Overtemperature /
short to ground
X
L
H
L
H
H
L
Cycling
Latched
0
V
SENSEH
V
SENSEH
Undervoltage X X L 0
Short to V
BAT
L
H
X
L
L
H
H
H
H
0
V
SENSEH
< Nominal
Open load Off-state
(with pull-up)
L
H
X
L
L
H
H
H
H
0
V
SENSEH
0
Negative output
voltage clamp
X L Negative 0