Datasheet
Electrical specifications VND5T016ASP-E
10/31 Doc ID 022687 Rev. 3
Figure 4. t
reset
definition
Table 7. Logic inputs
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Input low level voltage 0.9 V
I
IL
Low level input current V
IN
=0.9V 1 µA
V
IH
Input high level voltage 2.1 V
I
IH
High level input current V
IN
=2.1V 10 µA
V
I(hyst)
Input hysteresis voltage 0.25 V
V
ICL
Input clamp voltage
I
IN
=1mA 5.5 7
V
I
IN
=-1mA -0.7
V
FR_Stby_L
Fault_reset_standby low
level voltage
0.9 V
I
FR_Stby_L
Low level
fault_reset_standby
current
V
FR_Stby
=0.9V 1 µA
V
FR_Stby_H
Fault_reset_standby high
level voltage
2.1 V
I
FR_Stby_H
High level
fault_reset_standby
current
V
FR_Stby
=2.1V 10 µA
V
FR_Stby
(hyst)
Fault_reset_standby
hysteresis voltage
0.25 V
V
FR_Stby_CL
Fault_reset_standby
clamp voltage
I
FR_Stby
=15mA (10ms) 11 15
V
I
FR_Stby
=-1mA -0.7
t
reset
Overload latch-off reset
time
See Figure 5 224µs
t
stby
Standby delay See Figure 4 120 1200 µs
FR_STBY
IN
OUTPUT
CS
Overload
Channel
T_reset
FR_STBY
IN
OUTPUT
CS
Overload
Channel