Datasheet

Electrical specifications VND5E160J-E
14/34
Table 12. Electrical transient requirements
ISO 7637-2:
2004(E)
Test pulse
Test levels
Number of
pulses or
test times
Burst cycle / pulse
repetition time
Delays and
Impedance
III IV
1 -75 V -100 V
5000
pulses
0.5 s 5 s 2 ms, 10
2a +37 V +50 V
5000
pulses
0.2 s 5 s 50 s, 2
3a -100 V -150 V 1h 90 ms 100 ms 0.1 s, 50
3b +75 V +100 V 1h 90 ms 100 ms 0.1 s, 50
4 -6 V -7 V 1 pulse 100 ms, 0.01
5b
(2)
+65 V +87 V 1 pulse 400 ms, 2
ISO 7637-2:
2004(E)
Test pulse
Test level results
(1)
1. The above test levels must be considered referred to VCC = 13.5V except for pulse 5b.
III IV
1C C
2a C C
3a C C
3b C C
4C C
5b
(2)
2. Valid in case of external load dump clamp: 40V maximum referred to ground.
CC
Class Contents
C All functions of the device are performed as designed after exposure to disturbance.
E
One or more functions of the device are not performed as designed after exposure to
disturbance and cannot be returned to proper operation without replacing the device.