Datasheet

VND5E160AJ-E Electrical specifications
15/37
Figure 9. I
out
/ I
sense
vs. I
out
Figure 10. Maximum current sense ratio drift vs load current
Note: Parameter guaranteed by design; it is not tested.
200
250
300
350
400
450
500
550
600
650
700
0,35 0,58 0,81 1,04 1,27 1,5
max Tj = -40 °C to 150 °C
max Tj = 25 °C to 150 °C
min Tj = 25 °C to 150 °C
min Tj = -40 °C to 150 °C
typical value
I
out
/ I
sense
I
OUT
(A)
-15
-10
-5
0
5
10
15
0,35 0,58 0,81 1,04 1,27 1,5
I
OUT
(A)
dk/k(%)