Datasheet
VND5E160AJ-E Electrical specifications
11/37
Table 9. Current sense (8V<VCC<18V)
Symbol Parameter Test conditions Min. Typ. Max. Unit
K
0
I
OUT
/I
SENSE
I
OUT
= 0.025A; V
SENSE
= 0.5V; V
CSD
=0V;
T
j
= -40°C...150°C 270 520 730
K
1
I
OUT
/I
SENSE
I
OUT
= 0.35A; V
SENSE
=0.5V; V
CSD
=0V;
T
j
= -40°C...150°C
I
OUT
=0.35A; V
SENSE
=0.5V; V
CSD
=0V;
T
j
= 25°C...150°C
345
370
470
470
610
540
dK
1
/K
1
(1)
Current sense ratio
drift
I
OUT
= 0.35A; V
SENSE
= 0.5V;
V
CSD
=0V;
T
J
= -40 °C to 150 °C
-13 13 %
K
2
I
OUT
/I
SENSE
I
OUT
= 0.5A; V
SENSE
= 4V; V
CSD
= 0V;
T
j
= -40°C...150°C
I
OUT
= 0.5A; V
SENSE
= 4V; V
CSD
= 0V;
T
j
= 25°C...150°C
370
390
460
460
550
510
dK
2
/K
2
(1)
Current sense ratio
drift
I
OUT
= 0.5 A; V
SENSE
= 4 V;
V
CSD
= 0V;
T
J
= -40 °C to 150 °C
-8 8 %
K
3
I
OUT
/I
SENSE
I
OUT
= 1.5A; V
SENSE
=4V; V
CSD
=0V;
T
j
= -40°C...150°C
I
OUT
=1.5A; V
SENSE
=4V; V
CSD
=0V;
T
j
= 25°C...150°C
400
410
430
430
470
460
dK
3
/K
3
(1)
Current sense ratio
drift
I
OUT
= 1.5 A; V
SENSE
= 4 V;
V
CSD
=0V;
T
J
= -40 °C to 150 °C
-4 4 %
I
SENSE0
Analog sense
leakage current
I
OUT
=0A; V
SENSE
=0V;
V
CSD
=5V; V
IN
=0V; T
j
=-40°C...150°C
V
CSD
=0V; V
IN
=5V; T
j
=-40°C...150°C
I
OUT
=0.6A; V
SENSE
=0V;
V
CSD
=5V; V
IN
=5V; T
j
= -40°C...150°C
0
0
0
1
2
1
µA
µA
µA
I
OL
Openload ON state
current detection
threshold
V
IN
= 5V, 8V<V
CC
<18V
I
SENSE
= 5 µA
15mA
V
SENSE
Max analog
senseoutput
voltage
I
OUT
=1.5A; V
CSD
=0V; 5 V
V
SENSEH
(2)
Analog sense
output voltage in
fault condition
V
CC
=13V; R
SENSE
= 3.9K 8V
I
SENSEH
(2)
Analog sense
output current in
fault condition
V
CC
=13V; V
SENSE
= 5V; 9 mA