Datasheet

Electrical specifications VND5E006ASP-E
10/37 DocID17362 Rev 6
Table 7. Logic inputs
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Input low level voltage 0.9 V
I
IL
Low level input current V
IN
= 0.9 V 1 µA
V
IH
Input high level voltage 2.1 V
I
IH
High level input current V
IN
= 2.1 V 10 µA
V
I(hyst)
Input hysteresis voltage 0.25 V
V
ICL
Input clamp voltage
I
IN
= 1 mA 5.5 7 V
I
IN
= -1 mA -0.7 V
V
CSDL
CS_DIS low level voltage 0.9 V
I
CSDL
Low level CS_DIS current V
CSD
= 0.9 V 1 µA
V
CSDH
CS_DIS high level voltage 2.1 V
I
CSDH
High level CS_DIS current V
CSD
= 2.1 V 10 µA
V
CSD(hyst
)
CS_DIS hysteresis voltage 0.25 V
V
CSCL
CS_DIS clamp voltage
I
CSD
= 1 mA 5.5 7 V
I
CSD
= -1 mA -0.7 V
Table 8. Protections and diagnostics
(1)
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles.
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC short circuit current
V
CC
= 13 V 70 100 140 A
5 V < V
CC
< 24 V 140 A
I
limL
Short circuit current
during thermal cycling
V
CC
= 13 V; T
R
< T
j
< T
TSD
25 A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature
T
RS
+
1
T
RS
+
5
°C
T
RS
Thermal reset of status 135 °C
T
HYST
Thermal hysteresis
(T
TSD
-T
R
)
C
V
DEMAG
Turn-off output voltage
clamp
I
OUT
= 2 A; V
IN
= 0; L = 6 mH
V
CC
-
28
V
CC
-
31
V
CC
-
35
V
V
ON
Output voltage drop
limitation
I
OUT
=1 A; T
j
= -40 °C...150 °C
(see Figure 8)
25 mV