Electrical specifications VND5050J-E / VND5050K-E
10/37 Doc ID 12266 Rev 7
Table 9.
Protections
(1)
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles.
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC short circuit current
V
CC
=13V
5V<V
CC
<36V
12 18 24
24
A
A
I
limL
Short circuit current
during thermal cycling
V
CC
=13V
T
R
<T
j
<T
TSD
7A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature
T
RS
+ 1 T
RS
+ 5
°C
T
RS
Thermal reset of
STATUS
135 °C
T
HYST
Thermal hysteresis
(T
TSD
-T
R
)
7°C
t
SDL
Status delay in overload
conditions
T
j
>T
TSD
(see
Figure 4
)20µs
V
DEMAG
Turn-off output voltage
clamp
I
OUT
=2A; V
IN
=0; L=6mH
V
CC
-41 V
CC
-46 V
CC
-52
V
V
ON
Output voltage drop
limitation
I
OUT
= 0.1A;
T
j
= -40°C...+150°C
(see
Figure 6
)
25 mV
Table 10. Openload detection
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
OL
Openload on-state
detection threshold
V
IN
= 5V,8V<V
CC
<18V 10
See
Figure 19
70 mA
t
DOL(on)
Openload on-state
detection delay
I
OUT
= 0A, V
CC
=13V
(see Figure 4)
200 µs
t
POL
Delay between INPUT
falling edge and STATUS
rising edge in Openload
condition
I
OUT
= 0A (see
Figure 4
) 200 500 1000 µs
V
OL
Openload off-state
voltage detection
threshold
V
IN
= 0V, 8V<V
CC
<16V 2
See
Figure 20
4V
t
DSTKON
Output short circuit to
V
CC
detection delay at
turn-off
(see
Figure 4
)180t
POL
µs