Datasheet

Electrical specifications VND5050AJ-E / VND5050AK-E
10/37 Doc ID 12272 Rev 10
V
CSD(hyst)
CS_DIS hysteresis
voltage
0.25 V
V
CSCL
CS_DIS clamp voltage
I
CSD
= 1mA
I
CSD
= -1mA
5.5
-0.7
7V
V
Table 9.
Protections and diagnostics
(1)
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles.
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC short circuit current
V
CC
= 13V
5V<V
CC
<36V
12 18 24
24
A
A
I
limL
Short circuit current
during thermal cycling
V
CC
=13V; T
R
<T
j
<T
TSD
7A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature
T
RS
+ 1
T
RS
+ 5 °C
T
RS
Thermal reset of
STATUS
135 °C
T
HYST
Thermal hysteresis
(T
TSD
-T
R
)
C
V
DEMAG
Turn-off output voltage
clamp
I
OUT
=2A; V
IN
=0; L=6mH V
CC
-41 V
CC
-46 V
CC
-52 V
V
ON
Output voltage drop
limitation
I
OUT
=0.1A;
T
j
= -40°C...+150°C
(see Figure 9)
25 mV
Table 10. Current sense (8V<V
CC
<16V)
Symbol Parameter Test conditions Min. Typ. Max. Unit
K
0
I
OUT
/I
SENSE
I
OUT
=0.05A;
V
SENSE
=0.5V;V
CSD
=0V;
T
j
= -40°C...150°C
1270 2360 3450
K
1
I
OUT
/I
SENSE
I
OUT
=1A; V
SENSE
=0.5V;V
CSD
=0V;
T
j
= -40°C
T
j
= 25°C...150°C
1470
1570
2020
2020
2610
2470
dK
1
/K
1
(1)
Current sense ratio
drift
I
OUT
=1A; V
SENSE
= 0.5V;
V
CSD
=0V;
T
J
=-40 °C to 150 °C
-7 +7 %
K
2
I
OUT
/I
SENSE
I
OUT
=2A; V
SENSE
=4V;V
CSD
=0V;
T
j
= -40°C
T
j
= 25°C...150°C
1740
1790
2020
2020
2320
2250
Table 8. Logic input (continued)
Symbol Parameter Test conditions Min. Typ. Max. Unit