Datasheet

Electrical specification VND5025AK-E
10/32 Doc ID 12581 Rev 11
Table 8. Logic input
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Input low level voltage 0.9 V
I
IL
Low level input current V
IN
=0.9V 1 µA
V
IH
Input high level voltage 2.1 V
I
IH
High level input current V
IN
=2.1V 10 µA
V
I(hyst)
Input hysteresis voltage 0.25
VV
ICL
Input clamp voltage
I
IN
=1mA 5.5 7
I
IN
= -1mA -0.7
V
CSDL
CS_DIS low level voltage 0.9
I
CSDL
Low level CS_DIS current V
CSD
=0.9V 1 µA
V
CSDH
CS_DIS high level voltage 2.1 V
I
CSDH
High level CS_DIS current V
CSD
=2.1V 10 µA
V
CSD(hyst)
CS_DIS hysteresis voltage 0.25
V
V
CSCL
CS_DIS clamp voltage
I
CSD
=1mA 5.5 7
I
CSD
=-1mA -0.7
Table 9. Protection and diagnostics
(1)
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles.
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
LIMH
DC short circuit current
V
CC
= 13V 29 41
57
A
5V < V
CC
< 36V
I
LIML
Short circuit current
during thermal cycling
V
CC
= 13V;
T
R
<T
j
<T
TSD
16
T
TSD
Shutdown temperature 150 175 200
°C
T
R
Reset temperature T
RS
+1 T
RS
+5
T
RS
Thermal reset of STATUS 135
T
HYST
Thermal hysteresis
(T
TSD
-T
R
)
7
V
DEMAG
Turn-off output voltage
clamp
I
OUT
=2A;
V
IN
=0;
L=6mH
V
CC
-41 V
CC
-46 V
CC
-52 V
V
ON
Output voltage drop
limitation
I
OUT
=0.20.1A;
T
j
= -40°C to +150°C
(see Figure 9)
25 mV