Datasheet

Electrical specifications VND5012AK-E
10/31 Doc ID 12285 Rev 8
Table 8. Logic inputs
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Input low level voltage 0.9 V
I
IL
Low level input current V
IN
=0.9 V 1 µA
V
IH
Input high level voltage 2.1 V
I
IH
High level input current V
IN
=2.1 V 10 µA
V
I(hyst)
Input hysteresis voltage 0.25 V
V
ICL
Input clamp voltage
I
IN
=1 mA
I
IN
=-1 mA
5.5
-0.7
7V
V
V
CSDL
CS_DIS low level voltage 0.9 V
I
CSDL
Low level CS_DIS current V
CSD
=0.9 V 1 µA
V
CSDH
CS_DIS high level voltage 2.1 V
I
CSDH
High level CS_DIS current V
CSD
=2.1 V 10 µA
V
CSD(hyst)
CS_DIS hysteresis
voltage
0.25 V
V
CSCL
CS_DIS clamp voltage
I
CSD
=1 mA
I
CSD
=-1 mA
5.5
-0.7
7V
V
Table 9. Protections and diagnostics
(1)
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles.
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC short circuit current
V
CC
=13 V
5V<V
CC
<36 V
42 60 84
84
A
A
I
limL
Short circuit current
during thermal cycling
V
CC
=13 V T
R
<T
j
<T
TSD
24 A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature
T
RS
+ 1 T
RS
+ 5
°C
T
RS
Thermal reset of
STATUS
135 °C
T
HYST
Thermal hysteresis
(T
TSD
-T
R
)
C
V
DEMAG
Turn-off output voltage
clamp
I
OUT
=2 A; V
IN
=0;
L=6 mH
V
CC
-41 V
CC
-46 V
CC
-52
V
V
ON
Output voltage drop
limitation
I
OUT
= 0.4 A;
T
j
= -40 °C...+150 °C
(see
Figure 26
)
25 mV