Datasheet

Electrical specifications VN5E160AS-E
10/37 Doc ID 15609 Rev 4
Table 7. Logic inputs
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Low-level input voltage 0.9 V
I
IL
Low-level input current V
IN
= 0.9 V 1 µA
V
IH
High-level input voltage 2.1 V
I
IH
High-level input current V
IN
= 2.1 V 10 µA
V
I(hyst)
Hysteresis input voltage 0.25 V
V
ICL
Input voltage clamp
I
IN
= 1 mA 5.5 7
V
I
IN
= -1 mA -0.7
V
CSDL
Low-level CS_DIS voltage 0.9 V
I
CSDL
Low-level CS_DIS current V
CSD
= 0.9 V 1 µA
V
CSDH
High-level CS_DIS voltage 2.1 V
I
CSDH
High-level CS_DIS current V
CSD
= 2.1 V 10 µA
V
CSD(hyst)
Hysteresis CS_DIS voltage 0.25 V
V
CSCL
CS_DIS voltage clamp
I
CSD
= 1 mA 5.5 7
V
I
CSD
= -1 mA -0.7
Table 8. Protection and diagnostics
(1)
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles.
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC short-circuit
current
V
CC
= 13 V 7 10 14 A
5 V < V
CC
< 28 V 14 A
I
limL
Short-circuit current
during thermal cycling
V
CC
= 13 V
T
R
< T
j
< T
TSD
2.5 A
T
TSD
Shutdown
temperature
150 175 200 °C
T
R
Reset temperature T
RS
+ 1 T
RS
+ 5 °C
T
RS
Thermal reset of
STATUS
135 °C
T
HYST
Thermal hysteresis
(T
TSD
- T
R
)
C
V
DEMAG
Turn-off output
voltage clamp
I
OUT
= 1 A, V
IN
=0,
L=20mH
V
CC
-41 V
CC
-46 V
CC
-52 V
V
ON
Output voltage drop
limitation
I
OUT
= 0.03 A (see Figure 8)
T
j
= -40 °C to +150 °C
25 mV