Datasheet

Electrical specifications VN5E025AJ-E
10/37 Doc ID 13106 Rev 5
Table 7. Logic inputs
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Input low level voltage 0.9 V
I
IL
Low level input current V
IN
= 0.9V 1 µA
V
IH
Input high level voltage 2.1 V
I
IH
High level input current V
IN
= 2.1V 10 µA
V
I(hyst)
Input hysteresis
voltage
0.25 V
V
ICL
Input clamp voltage
I
IN
= 1mA
I
IN
= -1mA
5.5
-0.7
7V
V
V
CSDL
CS_DIS low level
voltage
0.9 V
I
CSDL
Low level CS_DIS
current
V
CSD
= 0.9V 1 µA
V
CSDH
CS_DIS high level
voltage
2.1 V
I
CSDH
High level CS_DIS
current
V
CSD
= 2.1V 10 µA
V
CSD(hyst)
CS_DIS hysteresis
voltage
0.25 V
V
CSCL
CS_DIS clamp voltage
I
CSD
=1mA
I
CSD
= -1mA
5.5
-0.7
7V
V
Table 8. Protection and diagnostics
(1)
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device operates under
abnormal conditions this software must limit the duration and number of activation cycles.
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC short circuit current
V
CC
= 13V
5V<V
CC
<28V
43 60 85
85
A
A
I
limL
Short circuit current
during thermal cycling
V
CC
= 13V; T
R
<T
j
<T
TSD
15 A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature T
RS
+ 1 T
RS
+ 5 °C
T
RS
Thermal reset of status 135 °C
T
HYST
Thermal hysteresis
(T
TSD
-T
R
)
C
V
DEMAG
Turn-Off output voltage
clamp
I
OUT
= 2A; V
IN
=0; L= 6mH V
CC
-41 V
CC
-46 V
CC
-52 V
V
ON
Output voltage drop
limitation
I
OUT
= 0.1A
T
j
= -40°C...150°C
(see Figure 8)
25 mV