Datasheet
VN5E010AH Electrical specifications
Doc ID 15984 Rev 3 9/37
2.3 Electrical characteristics
Values specified in this section are for 8 V < V
CC
< 28 V, -40 °C < T
j
< 150 °C, unless
otherwise specified.
Table 5. Power section
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
CC
Operating supply voltage 4.5 13 28 V
V
USD
Undervoltage shutdown 3.5 4.5 V
V
USDhyst
Undervoltage shutdown
hysteresis
0.5 V
R
ON
ON-state resistance
I
OUT
= 6 A; T
j
= 25 °C 10
mI
OUT
= 6 A; T
j
= 150 °C 20
I
OUT
= 6 A; V
CC
= 5 V; T
j
= 25 °C 13
R
ON-Rev
R
DSON
in reverse battery
condition
V
CC
= -13 V; I
OUT
= -6 A;
T
j
= 25 °C
10 m
V
clamp
Clamp voltage I
CC
= 20 mA; I
OUT
= 0 A 41 46 52 V
I
S
Supply current
OFF-state: V
CC
= 13 V; T
j
= 25 °C;
V
IN
= V
OUT
= V
SENSE
= 0 V
2 5 µA
ON-state: V
CC
= 13 V; V
IN
= 5 V;
I
OUT
= 0 A
1.5 3 mA
I
L(off)
OFF-state output current
V
IN
= V
OUT
= 0 V; V
CC
= 13 V;
T
j
= 25 °C
00.01 3
µA
V
IN
= V
OUT
= 0 V; V
CC
= 13 V;
T
j
= 125 °C
05
Table 6. Switching (V
CC
= 13 V, T
j
= 25 °C)
Symbol Parameter Test conditions Min. Typ. Max. Unit
t
d(on)
Turn-on delay time
R
L
= 2.2
(see Figure 6)
-40 -µs
t
d(off)
Turn-off delay time
R
L
= 2.2
(see Figure 6)
-28 -µs
(dV
OUT
/dt)
on
Turn-on voltage
slope
R
L
= 2.2 - (see Figure 26)- Vµs
(dV
OUT
/dt)
off
Turn-off voltage
slope
R
L
= 2.2 - (see Figure 28)- Vµs
W
ON
Switching energy
losses at turn-on
(t
won
)
R
L
= 2.2
(see Figure 6)
-2 -mJ
W
OFF
Switching energy
losses at turn-off
(t
woff
)
R
L
= 2.2
(see Figure 6)
-0.6 -mJ