VN5E010AH Electrical specifications
Doc ID 15984 Rev 3 11/37
Table 9. Current sense (8 V < V
CC
< 18 V)
Symbol Parameter Test conditions Min. Typ. Max. Unit
K
0
I
OUT
/I
SENSE
I
OUT
= 0.25 A; V
SENSE
= 0.5 V
T
j
= -40 °C to 150 °C
T
j
= 25 °C to 150 °C
3000
3000
7410
7410
12000
11600
K
1
I
OUT
/I
SENSE
I
OUT
= 6 A; V
SENSE
= 0.5 V
T
j
= -40 °C to 150 °C
T
j
= 25 °C to 150 °C
5350
5510
6740
6740
8500
7745
dK
1
/K
1
(1)
Current sense ratio drift
I
OUT
= 6 A; V
SENSE
= 0.5 V;
V
CSD
=0V;
T
j
= -40 °C to 150 °C
-15 15 %
K
2
I
OUT
/I
SENSE
I
OUT
= 10 A; V
SENSE
= 4 V
T
j
= -40 °C to 150 °C
T
j
= 25 °C to 150 °C
5850
5800
6570
6570
7690
7195
dK
2
/K
2
(1)
Current sense ratio drift
I
OUT
= 10 A; V
SENSE
= 4 V;
V
CSD
= 0 V;
T
j
= -40 °C to 150 °C
-11 11 %
K
3
I
OUT
/I
SENSE
I
OUT
= 25 A; V
SENSE
= 4 V
T
j
= -40 °C to 150 °C
T
j
= 25 °C to 150 °C
5915
5850
6420
6420
7000
6755
dK
3
/K
3
(1)
Current sense ratio drift
I
OUT
= 25 A; V
SENSE
= 4 V;
V
CSD
= 0 V;
T
j
= -40 °C to 150 °C
-8 8 %
I
SENSE0
Analog sense leakage
current
I
OUT
= 0 A; V
SENSE
= 0 V;
V
CSD
= 5 V; V
IN
=0 V;
T
j
= -40 °C to 150 °C
01
µA
I
OUT
= 0 A; V
SENSE
= 0 V;
V
CSD
= 0 V; V
IN
= 5 V;
T
j
= -40 °C to 150 °C
02
I
OUT
= 2 A; V
SENSE
= 0 V;
V
CSD
= 5 V; V
IN
= 5 V;
T
j
= -40 °C to 150 °C
1
I
OL
Open load ON-state
current detection
threshold
V
IN
= 5 V, 8 V < V
CC
< 18 V
I
SENSE
= 5 µA
580mA
V
SENSE
Max analog sense
output voltage
I
OUT
= 18 A; R
SENSE
= 3.9 k 5V
V
SENSEH
(2)
Analog sense output
voltage in fault condition
V
CC
= 13 V; R
SENSE
= 3.9 k 8V
I
SENSEH
(2)
Analog sense output
current in fault
condition
V
CC
= 13 V; V
SENSE
= 5 V 9 mA