Datasheet

Electrical specifications VN5E010AH
10/37 Doc ID 15984 Rev 3
Table 7. Logic inputs
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Low-level input voltage 0.9 V
I
IL
Low-level input current V
IN
= 0.9 V 1 µA
V
IH
High-level input voltage 2.1 V
I
IH
High-level input current V
IN
= 2.1 V 10 µA
V
I(hyst)
Input hysteresis voltage 0.25 V
V
ICL
Input clamp voltage
I
IN
= 1 mA 5.5 7
V
I
IN
= -1 mA -0.7
V
CSDL
Low-level CS_DIS voltage 0.9 V
I
CSDL
Low-level CS_DIS current V
CSD
= 0.9 V 1 µA
V
CSDH
High-level CS_DIS voltage 2.1 V
I
CSDH
High-level CS_DIS current V
CSD
= 2.1 V 10 µA
V
CSD(hyst)
CS_DIS hysteresis voltage 0.25 V
V
CSCL
CS_DIS clamp voltage
I
CSD
= 1 mA 5.5 7
V
I
CSD
= -1 mA -0.7
Table 8. Protection and diagnostics
(1)
1. To ensure long term reliability under heavy overload or short-circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
Short-circuit current
V
CC
= 13 V 60 85 120
A
5 V < V
CC
< 28 V 120
I
limL
Short-circuit current
during thermal cycling
V
CC
=13 V;
T
R
< T
j
< T
TSD
21 A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature T
RS
+ 1 T
RS
+ 5 °C
T
RS
Thermal reset of status 135 °C
T
HYST
Thermal hysteresis
(T
TSD
- T
R
)
C
V
DEMAG
Turn-off output voltage
clamp
I
OUT
= 2 A; V
IN
= 0;
L = 6 mH
V
CC
- 41 V
CC
- 46 V
CC
- 52 V
V
ON
Output voltage drop
limitation
I
OUT
= 0.5 A;
T
j
= -40 °C to 150 °C
25 mV