Datasheet

Electrical specification VN5772AK-E
10/34 Doc ID 16084 Rev 6
W
ON
Switching energy
losses during t
won
R
L
= 6.5 Ω (see Figure 4)— 0.24 mJ
W
OFF
Switching energy
losses during t
woff
R
L
= 6.5 Ω (see Figure 4)— 0.2 mJ
Table 8. Logic inputs
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Low-level input voltage 0.9 V
I
IL
Low-level input current V
IN
= 0.9 V 1 µA
V
IH
High-level input voltage 2.1 V
I
IH
High-level input current V
IN
= 2.1 V 10 µA
V
I(hyst)
Input voltage hysteresis 0.25 V
V
ICL
Input voltage clamp
I
IN
= 1 mA 5.5 7
V
I
IN
= -1 mA -0.7
Table 9. Protection and diagnostics
(1)
1. To ensure long-term reliability under heavy overload or short-circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles.
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC short-circuit
current
V
CC
= 13 V 12 18 24 A
5V<V
CC
<36V 24 A
I
limL
Short-circuit current
during thermal cycling
V
CC
= 13 V; T
R
< T
j
< T
TSD
7A
T
TSD
Shutdown
temperature
150 175 200 °C
T
R
Reset temperature T
RS
+ 1 T
RS
+ 5 °C
T
RS
Thermal reset of
STATUS
135 °C
T
HYST
Thermal hysteresis
(T
TSD
- T
R
)
C
V
DEMAG
Turn-off output voltage
clamp
I
OUT
= 2 A; V
IN
= 0; L = 6 mH V
CC
- 41 V
CC
- 46 V
CC
- 52 V
V
ON
Output voltage drop
limitation
I
OUT
= 0.1 A,
T
j
= -40 °C to 150 °C
(see Figure 5)
25 mV
Table 7. Switching (V
CC
= 13 V) (continued)
Symbol Parameter Test conditions Min. Typ. Max. Unit