Datasheet
Electrical specifications VN5050J-E
10/31
Table 8. Status pin (V
SD
=0V)
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
STAT
Status low output
voltage
I
STAT
= 1.6 mA, V
SD
=0V 0.5 V
I
LSTAT
Status leakage current
Normal Operation or V
SD
=5V,
V
STAT
= 5V
10 µA
C
STAT
Status pin input
capacitance
Normal Operation or V
SD
=5V,
V
STAT
= 5V
100 pF
V
SCL
Status clamp voltage
I
STAT
= 1mA
I
STAT
= -1mA
5.5
-0.7
7V
V
Table 9. Protections
(1)
(1) To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles.
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
limH
DC short circuit current
V
CC
= 13V
5V<V
CC
<36V
13.5 19 26.5
26.5
A
A
I
limL
Short circuit current
during thermal cycling
V
CC
= 13V
T
R
<T
j
<T
TSD
7A
T
TSD
Shutdown temperature 150 175 200 °C
T
R
Reset temperature
T
RS
+ 1 T
RS
+ 5
°C
T
RS
Thermal reset of
STATUS
135 °C
T
HYST
Thermal hysteresis
(T
TSD
-T
R
)
7°C
t
SDL
Status delay in overload
conditions
T
j
>T
TSD
(see Figure 4)20µs
V
DEMAG
Turn-Off output voltage
clamp
I
OUT
=2A; V
IN
=0; L=6mH
V
CC
-41 V
CC
-46 V
CC
-52
V
V
ON
Output voltage drop
limitation
I
OUT
= 0.1A;
T
j
= -40°C...+150°C
(see Figure 6)
25 mV