Datasheet
Electrical characteristics VN340SP-33-E
6/16
Note: If INPUT pin is floating the corresponding channel will automatically switch OFF. If GND pin
is disconnected, the channel will switch OFF provided V
CC
not exceed 36 V.
Table 6. Protection and diagnostic
Symbol Parameter Test conditions Min Typ Max Unit
V
DIAG
(1)
1. Status determination > 100 μs after the switching edge.
Status voltage output
low
I
DIAG
= 5 mA (Fault condition) 1 V
V
SCL
(
1
)
Status clamp voltage
I
DIAG
= 1 mA
I
DIAG
= 1 mA
32 36
-0.7
V
V
V
USD
Undervoltage shut
down
58V
I
LIM
DC Short circuit
current
V
CC
= 24 V; R
LOAD
< 10 mΩ 12A
I
OVPK
Peak short circuit
current
V
CC
= 24 V; V
IN
= 30 V;
R
LOAD
< 10 mΩ
4A
I
DIAGH
Leakage ondiag pin in
high state
V
DIAG
= 24 V 25 μΑ
I
LOAD
Output leakage
current
V
CC
= 10 to 36 V; V
IN
= V
IL
50 μΑ
t
SC
Delay time of current
limiter
100 μs
T
TSD
Thermal shut down
temperature
150 170 °C
T
R
Thermal reset
temperature
135 155 °C