Datasheet
VIPer53 - E Transconductance error amplifier
27/36
The lowest load gives another condition for stability: The frequency F
BW1
must not encounter
the second order slope generated by the load pole and the integrator part of the error
amplifier. This condition can be met by adjusting the C
COMP
value:
Equation 13
The above formula gives a minimum value for C
COMP
. It can be then increased to provide a
natural soft start function as this capacitor is charged by the error amplifier current capacity
I
COMPhi
at start-up.
Figure 22. Typical compensation network
C
COMP
R
L1
C
OUT
⋅
6.3 Gm R
COMP
2
⋅⋅
------------------------------------------------------
P
OUT1
P
MAX
-------------------⋅>
P
OUT1
V
OUT
2
R
L1
---------------=
With:
15V
VDD
OSC
DRAIN
SOURCECOMPTOVL
Rcomp
Ccomp
10nF