Datasheet

VIPer53 - E Operation pictures
13/36
Figure 14. Error amplifier test cpfiguration
This configuration is for test purpose only. In order to insure a correct stability of the error
amplifier, a capacitor of 10nF (minimum value: 8nF) should be always connected between
COMP pin and ground. See figures Figure 18, 19 and 22.
Figure 15. Error amplifier transfer function
15V
VDD
OSC
DRAIN
SOURCECOMPTOVL
R
2.5 V
Vin
Vout
-60
-40
-20
0
20
40
60
Gain (dB)
Frequency (Hz)
Open
R = 10 k
R = 2.2 k
R = 470
1 10 100 1k 10k 100k 1M 10M