Datasheet

Table Of Contents
Electrical data VIPER37
10/35 Doc ID 022218 Rev 1
Table 8. Controller section (continued)
Symbol Parameter Test condition Min. Typ. Max. Unit
Overcurrent protection (2
nd
OCP)
I
DMAX
Second overcurrent
threshold
1.7 A
Overvoltage protection
V
OVP
Overvoltage protection
threshold
2.733.3V
T
STROBE
Overvoltage protection
strobe time
2.2 us
Brownout protection
V
BRth
Brownout threshold Voltage falling 0.41 0.45 0.49 V
V
BRhyst
Voltage hysteresis above
V
BRth
Voltage rising 50 mV
I
BRhyst
Current hysteresis 7 12 µA
V
BRclamp
Clamp voltage I
BR
= 250 µA 3 V
V
DIS
Brownout disable voltage 50 150 mV
Thermal shutdown
T
SD
Thermal shutdown
temperature
150 160 °C
T
HYST
Thermal shutdown
hysteresis
30 °C