Datasheet

Electrical data VIPER27
8/31 Doc ID 15133 Rev 5
Symbol Parameter Test condition Min Typ Max Unit
Brown out protection
V
BRth
Brown out threshold Voltage falling 0.41 0.45 0.49 V
V
BRhyst
Voltage hysteresis above V
BRth
Voltage rising 50 mV
I
BRhyst
Current hysteresis 7 12 μA
V
BRclamp
Clamp voltage I
BR
= 250 µA 3 V
V
DIS
Brown out disable voltage 50 150 mV
Thermal shutdown
T
SD
Thermal shutdown temperature 150 160 °C
T
HYST
Thermal shutdown hysteresis 30 °C
Table 8. Controller section (continued)