Datasheet
VIPer22A-E, VIPer22ADIP-E, VIPer22AS-E Electrical data
Doc ID 12050 Rev 2 3/21
1 Electrical data
1.1 Maximum ratings
Stressing the device above the rating listed in the “absolute maximum ratings” table may
cause permanent damage to the device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in the operating sections of
this specification is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.
1.2 Thermal data
Table 2. Absolute maximum rating
Symbol Parameter Value Unit
V
DS(sw)
Switching drain source voltage (T
J
= 25 ... 125 °C)
(1)
1. This parameter applies when the start-up current source is OFF. This is the case when the VDD voltage
has reached V
DDon
and remains above V
DDoff
.
-0.3 ... 730 V
V
DS(st)
Start-up drain source voltage (T
J
= 25 ... 125 °C)
(2)
2. This parameter applies when the start up current source is on. This is the case when the VDD voltage has
not yet reached V
DDon
or has fallen below V
DDoff.
-0.3 ... 400 V
I
D
Continuous drain current Internally limited A
V
DD
Supply voltage 0 ... 50 V
I
FB
Feedback current 3 mA
V
ESD
Electrostatic discharge:
Machine model (R = 0 Ω; C = 200 pF)
Charged device model
200
1.5
V
kV
T
J
Junction operating temperature Internally limited °C
T
C
Case operating temperature -40 to 150 °C
T
stg
Storage temperature -55 to 150 °C
Table 3. Thermal data
Symbol Parameter SO-8 DIP-8 Unit
R
thJC
Thermal resistance junction - case Max 25 15 °C/W
R
thJA
Thermal resistance junction - ambient
(1)
1. When mounted on a standard single-sided FR4 board with 200 mm
2
of Cu (at least 35 µm thick) connected
to all DRAIN pins.
Max 55 45 °C/W