24/32 DocID14419 Rev 9
Figure 30. Burst mode timing diagram, light load management
7.12 Brown-out protection
Brown-out protection is a not-latched shutdown function activated when a condition of mains
under voltage is detected. The Brown-out comparator is internally referenced to V
BRth
threshold, see Table 8 on page 7, and disables the PWM if the voltage applied at the BR pin
is below this internal reference. Under this condition the power MOSFET is turned off. Until
the Brown out condition is present, the V
DD
voltage continuously oscillates between the
V
DDon
and the UVLO thresholds, as shown in the timing diagram of Figure 31 on page 25. A
voltage hysteresis is present to improve the noise immunity.
The switching operation is restarted as the voltage on the pin is above the reference plus
the before said voltage hysteresis. See Figure 5 on page 9.
The Brown-out comparator is provided also with a current hysteresis, I
BRhyst
. The designer
has to set the rectified input voltage above which the power MOSFET starts switching after
brown out event, V
INon
, and the rectified input voltage below which the power MOSFET is
switched off, V
INoff
. Thanks to the I
BRhyst
, see Table 8 on page 7, these two thresholds can
be set separately.
I
DRAIN
V
FBbm
V
FB
t
t
50 mV
hyster.
Burst-mode
Normal - mode
Normal - mode
t
t
50 mV
hyster.
Burst-mode Burst-mode
Normal - mode Normal - mode
Normal - mode Normal - mode