Datasheet
DocID14419 Rev 9 15/32
VIPER17 Operation descriptions
32
C
VDD
capacitor must be sized enough to avoid fast discharge and keep the needed voltage
value higher than V
DDoff
threshold. In fact, a too low capacitance value could terminate the
switching operation before the controller receives any energy from the auxiliary winding.
The following formula can be used for the V
DD
capacitor calculation:
Equation 1
The t
SSaux
is the time needed for the steady state of the auxiliary voltage. This time is
estimated by applicator according to the output stage configurations (transformer, output
capacitances, etc.).
During the converter start up time, the drain current limitation is progressively increased to
the maximum value. In this way the stress on the secondary diode is considerably reduced.
It also helps to prevent transformer saturation. The soft-start time lasts 8.5 ms and the
feature is implemented for every attempt of start up converter or after a fault.