Datasheet
Characteristics USBULC6-2F3
4/9 DocID12970 Rev 4
Figure 9. S21 (dB) attenuation measurement
S21 dB
100k 1M 10M 100M 1G 10G
-10
-8
-6
-4
-2
0
F (Hz)
Figure 10. Peak pulse power versus initial
junction temperature (maximum values, pulse
8/20 µs)
Figure 11. Peak pulse power versus exponential
pulse duration (maximum values)
P
pp
(W)
0
20
40
60
80
100
120
140
0 25 50 75 100 125 150
A1 and A2 / GND, 8/20 µs
T
j
(°C)
Ppp (W)
1
10
100
1000
10 100 1000
t
P
(µs)
T
j
= 25° C
A1 and A2 / GND
Figure 12. Clamping voltage versus peak pulse
current (typical values, pulse 8/20 µs)
Figure 13. Leakage current versus junction
temperature (typical values)
0.1
1.0
10.0
100.0
05
10
15 20 25 30
Ipp (A)
V
CL
(V)
T
j
initial =25° C
25 50 75 100 125
T
j
(°C)
V
R
=3 V
I
R
(nA)
100.00
10.00
1.00
0.10
0.01
A1 / GND
A2 / GND