Datasheet

Absolute maximum ratings and operating conditions TSX56x, TSX56xA
4/28 DocID023274 Rev 4
2 Absolute maximum ratings and operating conditions
Table 2. Absolute maximum ratings (AMR)
Symbol Parameter Value Unit
V
CC
Supply voltage
(1)
1. All voltage values, except differential voltage, are with respect to network ground terminal.
18
VV
id
Differential input voltage
(2)
2. The differential voltage is the non-inverting input terminal with respect to the inverting input terminal.
±V
CC
V
in
Input voltage
(3)
3. V
CC
- V
in
must not exceed 18 V, V
in
must not exceed 18 V.
V
CC-
- 0.2 to V
CC+
+ 0.2
I
in
Input current
(4)
4. Input current must be limited by a resistor in series with the inputs.
10 mA
T
stg
Storage temperature -65 to +150 °C
R
thja
Thermal resistance junction to ambient
(5)(6)
SOT23-5
DFN8 2x2
MiniSO8
SO8
QFN16 3x3
TSSOP14
5. Short-circuits can cause excessive heating and destructive dissipation.
6. R
th
are typical values.
250
120
190
125
80
100
°C/W
R
thjc
Thermal resistance junction to case
DFN8 2x2
QFN16 3x3
33
30
T
j
Maximum junction temperature 150 °C
ESD
HBM: human body model
(7)
7. Human body model: 100 pF discharged through a 1.5 kΩ resistor between two pins of the device, done for
all couples of pin combinations with other pins floating.
4kV
MM: machine model for TSX561
(8)
8. Machine model: a 200 pF cap is charged to the specified voltage, then discharged directly between two
pins of the device with no external series resistor (internal resistor < 5 Ω), done for all couples of pin
combinations with other pins floating.
200
V
MM: machine model for TSX562 and TSX564
(8)
100
CDM: charged device model
(9)
9. Charged device model: all pins plus package are charged together to the specified voltage and then
discharged directly to ground.
1.5 kV
Latch-up immunity 200 mA
Table 3. Operating conditions
Symbol Parameter Value Unit
V
CC
Supply voltage 3 to 16
V
V
icm
Common mode input voltage range V
CC-
- 0.1 to V
CC+
+ 0.1
T
oper
Operating free air temperature range -40 to +125 °C