Absolute maximum ratings and operating conditions TSV63x, TSV63xA
4/30 Doc ID 15688 Rev 5
2 Absolute maximum ratings and operating conditions
Table 2. Absolute maximum ratings (AMR)
Symbol Parameter Value Unit
V
CC
Supply voltage
(1)
1. All voltage values, except differential voltage are with respect to network ground terminal.
6
VV
id
Differential input voltage
(2)
2. Differential voltages are the non-inverting input terminal with respect to the inverting input terminal.
±V
CC
V
in
Input voltage
(3)
3. V
CC
-V
in
must not exceed 6 V, V
in
must not exceed 6 V.
V
CC-
- 0.2 to V
CC+
+ 0.2
I
in
Input current
(4)
4. Input current must be limited by a resistor in series with the inputs.
10 mA
SHDN Shutdown voltage
(3)
V
CC-
- 0.2 to V
CC+
+ 0.2 V
T
stg
Storage temperature -65 to +150 °C
R
thja
Thermal resistance junction to ambient
(5)(6)
DFN8 2x2
SOT23-8
MiniSO-8
SO-8
MiniSO-10
TSSOP14
TSSOP16
QFN16 3x3
5. Short-circuits can cause excessive heating and destructive dissipation.
6. R
th
are typical values.
57
105
190
125
113
100
95
39
°C/W
T
j
Maximum junction temperature 150 °C
ESD
HBM: human body model
(7)
7. Human body model: 100 pF discharged through a 1.5 kΩ resistor between two pins of the device, done for
all couples of pin combinations with other pins floating.
4kV
MM: machine model
(8)
8. Machine model: a 200 pF cap is charged to the specified voltage, then discharged directly between two
pins of the device with no external series resistor (internal resistor < 5 Ω), done for all couples of pin
combinations with other pins floating.
300 V
CDM: charged device model
(9)
9. Charged device model: all pins plus package are charged together to the specified voltage and then
discharged directly to the ground.
1.5 kV
Latch-up immunity 200 mA
Table 3. Operating conditions
Symbol Parameter Value Unit
V
CC
Supply voltage 1.5 to 5.5
V
V
icm
Common mode input voltage range V
CC-
- 0.1 to V
CC+
+ 0.1
T
oper
Operating free air temperature range -40 to +125 °C