Datasheet

TSH343 Absolute maximum ratings and operating conditions
3/17
1 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings (AMR)
Symbol Parameter Value Unit
V
CC
Supply voltage
(1)
1. All voltage values, except differential voltage, are with respect to network terminal.
6V
V
in
Input voltage range
(2)
2. The magnitude of input and output voltages must never exceed V
CC
+0.3V.
0 to +1.4 V
T
oper
Operating free air temperature range -40 to +85 °C
T
stg
Storage temperature -65 to +150 °C
T
j
Maximum junction temperature 150 °C
R
thjc
SO8 thermal resistance junction to case 28 °C/W
R
thja
SO8 thermal resistance junction to ambient area 157 °C/W
P
max
Maximum power dissipation (@T
amb
=25°C) for T
j
=150°C 800 mW
ESD
CDM: charged device model
HBM: human body model
MM: machine model
2
1.5
200
kV
kV
V
Table 2. Operating conditions
Symbol Parameter Value Unit
V
CC
Power supply voltage 3 to 5.5
(1)
1. Tested in full production at 0V/5V single power supply.